个性化文献订阅>期刊> OPTICS EXPRESS
 

Thermal independent Silicon-Nitride slot waveguide biosensor with high sensitivity

  作者 Tu, XG; Song, JF; Liow, TY; Park, MK; Yiying, JQ; Kee, JS; Yu, MB; Lo, GQ  
  选自 期刊  OPTICS EXPRESS;  卷期  2012年20-3;  页码  2640-2648  
  关联知识点  
 

[摘要]As the sensitivity and detection limit of photonic refractive index (RI) biosensor increases, the temperature dependence becomes a major challenge. In this paper, we present a Mach-Zehnder Interferometer (MZI) biosensor based on silicon nitride slot waveguides. The biosensor is designed for minimal temperature dependence without compromising the performance in terms of sensitivity and detection limit. With air cladding, the measured surface sensitivity and detection limit of MZI biosensor reach 7.16 nm/(ngmm(-2)) and 1.30 (pgmm(-2)), while achieving a low temperature dependence is 5.0 pm/degrees C. With water cladding, the measured bulk sensitivity and detection limit reach 1730(2 pi)/RIU and 1.29 x 10(-5) RIU respectively. By utilizing Vernier effect through cascaded MZI structures, the measured sensitivity enhancement factor is 8.38, which results in a surface detection limit of 0.155 (pgmm(-2)). (C) 2012 Optical Society of America

 
      被申请数(0)  
 

[全文传递流程]

一般上传文献全文的时限在1个工作日内