个性化文献订阅>期刊> Journal of controlled release
 

Effect of controlled laser microporation on drug transport kinetics into and across the skin

  作者 Bachhav, YG; Summer, S; Heinrich, A; Bragagna, T; Bohler, C; Kalia, YN  
  选自 期刊  Journal of controlled release;  卷期  2010年146-1;  页码  31-36  
  关联知识点  
 

[摘要]The objectives of this study were to investigate a novel laser microporation technology ( PLEASE. Painless Laser Epidermal System) and to determine the effect of pore number and depth on the rate and extent of drug delivery across the skin. In addition, the micropores were visualized by confocal laser scanning microscopy and histological studies were used to determine the effect of laser fluence (energy applied per unit area) on pore depth. Porcine ear skin was used as the membrane for both the pore characterization and drug transport studies. Confocal images in the XY-plane revealed that the pores were typically 150-200 pm in diameter. Histological sections confirmed that fluence could be used to effectively control pore depth low energy application (4.53 and 13.59 J/cm(2)) resulted in selective removal of the stratum corneum (20-30 mu m), intermediate energies (e.g., 22.65 J/cm(2)) produced pores that penetrated the viable epidermis (60-100 mu m) and higher application energies created pores that reached the dermis (>150-200 mu m). The effects of pore number and pore depth on molecular transport were quantified by comparing lidocaine delivery kinetics across intact and porated skin samples. After 24 h, cumulative skin permeation of lidocaine with 0 (control), 150,300, 450 and 900 pores was 107 +/- 46, 774 +/- 110, 1400 +/- 344, 1653 +/- 437 and 1811 +/- 642 mu g/cm(2), respectively; there was no statistically significant difference between 300, 450 and 900 pore data - probably due to the effect of drug depletion since >50% of the applied dose was delivered. Importantly, increasing fluence did not produce a statistically significant increase in lidocaine permeation; after 24 h, cumulative lidocaine permeation was 1180 +/- 448, 1350 +/- 445, 1240 +/- 483 and 1653 +/- 436 mu g/cm(2) at fluences of 22.65, 45.3, 90.6 and 135.9 J/cm(2), respectively. Thus, shallow pores were equally effective in delivering lidocaine. Increasing lidocaine concentration in the formulation from 10 to 25 mg/ml produced a corresponding increase in permeation (at 24 h, 1650 +/- 437 and 4005 +/- 1389 mu g/cm(2), respectively). The validity of the porcine skin model was confirmed as transport across porcine and human skins was shown to be statistically equivalent (at 24 h, 1811 +/- 642 and 2663 +/- 208 mu g/cm(2), respectively). The clinical potential of the technology and its capacity to provide significantly faster delivery than conventional passive administration was demonstrated in short duration experiments involving application of a marketed lidocaine cream (LMX4 (R)) to laser-porated skin; after only 5 min of formulation application, lidocaine deposition was measured at 61.3 +/- 7.5 mu g/cm(2). In conclusion, the results demonstrate the ability of P.L.E.A.S.E.(R) (i) to create well-defined conduits in the skin, (ii) to provide a controlled enhancement of transdermal transport and (iii) to enable improvement in both the rate and extent of drug delivery. (C) 2010 Elsevier B.V. All rights reserved.

 
      被申请数(0)  
 

[全文传递流程]

一般上传文献全文的时限在1个工作日内