个性化文献订阅>期刊> RENEWABLE ENERGY
 

High efficiency pool filtering systems utilising variable frequency drives

  作者 Hameiri, Z.; Spooner, T.; Sproul, A. B.  
  选自 期刊  RENEWABLE ENERGY;  卷期  2009年34-2;  页码  450-455  
  关联知识点  
 

[摘要]Over 1 year, private swimming pools in Australia will typically consume 1680 GWh of electricity, producing 2130 kt of CO2. Redesigning a pool's filtration system and using it more efficiently can reduce the energy use, and hence the CO2 production, by a significant amount. This paper describes experimental measurements carried out on a new design of pool pump system. Initial experiments using a variable frequency drive (VFD) with a standard, single phase pump/motor system have achieved energy savings of 40%. Utilising a VFD and a three phase pump/motor energy savings of 61% have been achieved, without degrading the system performance. (C) 2008 Elsevier Ltd. All rights reserved.

 
      被申请数(0)  
 

[全文传递流程]

一般上传文献全文的时限在1个工作日内