个性化文献订阅>期刊> ENERGY
 

Sensitivity analysis of steam power plant-binary cycle

  作者 Rosyid, H; Koestoer, R; Putra, N; Nasruddin; Mohamad, AA; Yanuar  
  选自 期刊  ENERGY;  卷期  2010年35-9;  页码  3578-3586  
  关联知识点  
 

[摘要]This paper analyses a steam power two-stage binary cycle plant (SPP-2BCP), in which low temperature waste heat from a conventional steam power plant can be efficiently utilized to generate electricity by installing a bottoming binary cycle. The result from a previous calculation on the installation of binary cycle technology on a Steam Power Plant (SPP) with n-Pentane working fluid indicates an increase in plant efficiency of about 9%. The purpose of this study is to analyze the sensitivity of performance of the binary cycle system against variations in the SPP operational load and the condenser's cooling water temperature. The calculation is conducted on SPP load variations of 25%, 50%, 75% and 100%, inlet turbine pressure variations of 5 bar-30 bar, and inlet turbine temperature variations of 125 degrees C up to 235 degrees C. Each of these is also analyzed with ambient cooling water temperatures of 30 degrees C-37 degrees C. The results of the analysis indicate that the performance of this binary cycle SPP degrades slightly with SPP load, turbine inlet temperature, and turbine inlet pressure variations and with cooling water variations. (C) 2010 Elsevier Ltd. All rights reserved.

 
      被申请数(0)  
 

[全文传递流程]

一般上传文献全文的时限在1个工作日内