- Application of piezoresistive stress sensors in ultra thin device handling and characterization
[作者:Zhang, XW; Kumar, A; Zhang, QX; Ong, YY; Ho, SW; Khong, CH; Kripesh, V; Lau, JH; Kwong, DL; Sundaram, V; Tummula, RR; Meyer-Berg, G,期刊:Sensors And Actuators A-Physical, 页码:2-7 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- Because of 3D integration, thickness of Silicon wafer is thinner and thinner. For thin silicon ICs, challenges in wafer thinning, handling and assembly process increase. The piezoresistive stress sensors studied in this ...
- Design of a 2 Mbps FSK near-field transmitter for wireless capsule endoscopy
[作者:Thone, J; Radiom, S; Turgis, D; Carta, R; Gielen, G; Puers, R,期刊:Sensors And Actuators A-Physical, 页码:43-48 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- This paper introduces a novel and simple topology for an efficient, miniaturized, low power but high data rate transmitter, suitable for implanted devices. The application envisaged is in capsular endoscopy, where high q...
- A miniaturized wireless control platform for robotic capsular endoscopy using advanced pseudokernel approach
[作者:Susilo, E; Valdastri, P; Menciassi, A; Dario, P,期刊:Sensors And Actuators A-Physical, 页码:49-58 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- A ZigBee compliant wireless controller which manages multiple tasks, such as acquiring data from sensors and driving actuators, has been purposely developed for robotic capsular endoscopy applications. Preemptive priorit...
- Saw-tooth vernier ratchets for electrostatic inchworm actuators
[作者:Erismis, MA; Neves, HP; Puers, R; Van Hoof, C,期刊:Sensors And Actuators A-Physical, 页码:66-71 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- MEMS ratchets are used for positioning applications. The precision of positioning is related to the size of the ratchet and the minimum feature size of the microfabrication process. A new, saw-tooth shape, vernier ratche...
- An integrated vision system with autofocus for wireless capsular endoscopy
[作者:Cavallotti, C; Piccigallo, M; Susilo, E; Valdastri, P; Menciassi, A; Dario, P,期刊:Sensors And Actuators A-Physical, 页码:72-78 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- A prototype of a vision system for capsular endoscopy provided with autofocus function was developed. It is composed by two main parts: a wireless capsule with an adjustable focus in the range between 15 mm and 100 mm, a...
- Design and implementation of advanced systems in a flexible-stretchable technology for biomedical applications
[作者:Carta, R; Jourand, P; Hermans, B; Thone, J; Brosteaux, D; Vervust, T; Bossuyt, F; Axisa, F; Vanfleteren, J; Puers, R,期刊:Sensors And Actuators A-Physical, 页码:79-87 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- This paper presents the design and implementation of an advanced system on flexible and stretchable technology. The technology platform consists of a matrix of flexible non-stretchable functional islands linked together ...
- Uncooled infrared thermo-mechanical detector array: Design, fabrication and testing
[作者:Toy, MF; Ferhanoglu, O; Torun, H; Urey, H,期刊:Sensors And Actuators A-Physical, 页码:88-94 , 文章类型: Proceedings Paper,,卷期:2009年156-1]
- Thermo-mechanical detector arrays in the 160 x 120 array format are designed, fabricated, and tested. Detectors are composed of SiNx and TiN as absorbing layer, Al to form bimaterial legs, and integrated diffraction grat...
|